Graphite 52M - Heated FID Volatile Organic Compounds Analyzer

Graphite 52M - Heated FID Volatile Organic Compounds Analyzer


 

Graphite 52M - Heated FID Volatile Organic Compounds (VOC) Analyzer

Graphite 52M - Portable Heated FID Volatile Organic Compounds (VOC) Analyzer

The Graphite 52M is available in 3 different versions to meet your analytical requirements.

  • GRAPHITE 52M-S: Total HC monitoring
  • GRAPHITE 52M-D: Total HC, NmHC and CH4 simultaneous monitoring
  • GRAPHITE 52M-W Total HC monitoring on 2 independent lines



Download Download Brochure
 
For more information on this product, contact us:
Contact Altech USA Enviromental sales@altechusa.com
  • Engine exhaust gas monitoring

  • Standard Reference Method for Emission monitoring

  • Combustion and process control in all fields of application

  • Laboratories and Research Centers...

  • Fitted with FID for continuous and simultaneous measurement of Total Hydrocarbons (THC), Non-methanic Hydrocarbons (NmHC) and Methane (CH4)

  • Up to 191°C heated detector for HC measurement

  • Fast response time, designed to measure wet and corrosive sample

  • Graphic Liquid Crystal Display (LCD)

  • Interactive menu driven software with enhanced speed display

  • Real time calibration graph

  • User adjustable response time and averaging time

  • High efficiency long-life catalyst

  • Built-in memory for data storage

  • Internal zero and burner air scrubber

  • Communication by AK protocol (RS 232 / RJ45)

  • Built-in Ethernet TCP/IP connection for remote control and serial interface RS 232

  • Easy access to all components

  • Also available as portable analyzer

  • Ranges: 0-10/100/1,000/10,000 ppm or optionally 0-30/300/3,000/30,000

  • Accuracy: < 1% of reading between 15% and 100% of Full Scale (F.S.)

  • Noise: < 0.5% of F.S.

  • Response time:

    • < 1.5 sec. (THC)

    • < 3.5 sec. (CH4)

  • Lower detectable limit: 0.05 ppm on the 10 ppm range

  • Span drift: <1% / 24 h

  • Zero drift: < 1% / 24 h

  • Linearity: <1% for a concentration between 10% and 100% of the full scale’s range

  • Heated block temperature: up to 191°C

  • Sample flow rate: 0.7 to 2 l/min at 20 psi

  • Capillary block temperature: heated up to 180°C

  • Converter efficiency rate: > 99%

  • Housing: Standard 19 ‘’ – 4U rack

  • Dimensions: 483 x 470 x 177 mm (L x W x H)

  •  19 x 17.3 x 5.3 inches (L x W x H)

  • Weight: 22 kg / 48 lbs

  • Operating temperature: +5 to +45 °C

  • Power supply: 230 VAC, 50 Hz or 115 VAC,60Hz

  • Power consumption: 500 VA during start up

  • Communication: RS 232 & TCP/IP, AK protocol

  • Ethernet port

  • External dilution system for high concentrations up to 100,000 ppm

  • Internal zero and burner air scrubber

  • External air compressor / generator

  • Memory extension

  • Temperature regulated heated line with SS 2µm

  • built-in filter (up to 5m)

  • ESTEL electronic board (1 or 2) with:

    • 4 independent analog inputs

    • 4 independent analog outputs

    • 4 remote control inputs

    • 6 dry contacts outputs

  • SOREL electronic board with:

    • 4 dry contacts outputs

    • 4 dry contacts inputs

  • Special version without LCD screen for integration in engine gas cabinet