South American Chinese Italian French Dutchenese
MMS - Multiparameter Micro Monitoring Station

MMS – Multiparameter Micro Monitoring Station

Fixed or portable


 

MMS - Multiparameter Micro Monitoring Station for the continuous measurement of CO, CO2, O3, NO, NOx and NO2 (SO2 optionally)

Air Quality Turnkey Micro Monitoring Station

The Micro Monitoring Station (MMS) consists of a single IP54 enclosure where up to 3 measuring 2M Series modules can be housed.

This system meets the requirements of the biggest problems that pose the Air Quality monitoring: to find free space for a shelter. This problem is becoming more important in countries where local Government must monitor the increasing pollution. These «key points» can typically be narrow pavements with high buildings which edge both sides. 

The MMS is composed of autonomous modules based upon their different analysis principles:
1. Chemiluminescence (NO, NO2, NOx)
2. UV Photometry (O3)
3. IR Gas Filter Correlation (CO, CO2)
4. UV Fluorescence (SO2)


Download Download Brochure
 
For more information on this product, contact us :
Contact Altech USA Enviromental sales@altechusa.com
  • Tunnel Monitoring

  • Roadside air quality monitoring, traffic pollution control

  • Mobile Air Quality Monitoring

  • Ambient Air Pollution Hotspot Monitoring

  • Fence Line Monitoring for Industry

  • Indoor air quality monitoring (risk assessment in work places)

  • Measurement Campaigns and Monitoring Studies...

  • One single box for the continuous measurement of CO, CO2, O3, NO, NOx and NO(SO2 optionally)

  • Modular system 

  • USB and Ethernet TCP-IP for remote monitoring, data recovery and maintenance

  • Built-in Graphic LCD display for local data viewing

  • Display of real-time synoptic flow chart for each module

  • Cross interference correction, linearization, data smoothing

  • 1/4h average data storage over 1 year

  • USB and Ethernet TCP-IP for remote monitoring, data recovery and maintenance

  • Options: Integrated Data Acquisition System and XR® data management software 

  • Can be completed with PM162M particulate sampler, with MP101M or CPA for complementary real time particulate analysis

GENERAL SPECIFICATIONS:

  • Analyzers’ dimensions (WxHxD): 600x600x200mm

  • Weight (analyzer alone): 29 kg (63.9 lbs)

  • Power supply: 230 V / 50 Hz or 115 V / 60 Hz

  • Power consumption: 300 W approx

  • Operating  temperature: 

    •  A/C street cabinet version: -20 to +45°C

    • Portable version: +5 to + 38°C

  • Linearity: ± 1%

  • Output: 1 RS 232 / 422 and 2 Ethernet ports

DETAILED SPECIFICATIONS: 
Modular design, up to 3 of following modules (available configurations upon request):

NO / NO2 / NOx: 

  • Ranges: programmable from 0.1 to 20 ppm

  • Lower detectable limit: <0.4 ppb

  • Zero drift: <0.5 ppb / 24h

  • NH3 interference: <1% 

O3:

  • Ranges: programmable from 0.1 to 10 ppm 

  • Lower detectable limit: <0.4 ppb

  • Zero drift: <0.5 ppb / 24h

CO / CO2:

  • Ranges: programmable from 0.1 to 200 ppm (0 to 3,000 ppm for CO2)

  • Zero drift: <0.05 ppm / 24h 

  • Lower detectable limit: 40 ppb (CO)

SO2:

  • Ranges :  programmable from 0.1 to 10 ppm

  • Zero drift: <0.5 ppb / 24h 

  • Lower detectable limit: 0.4 ppb

  • Small footprint A/C shelter version with possible integration of: PM sampler or analyzer, meteo sensors

  • Analog outputs/inputs board

  • Additional CO2 measurement (option of the CO module)

  • Common zero air

  • External sample dryer

  • Ozone generator 

  • Span gas cylinders calibration SV

  • Sampling inlets