South American Chinese Italian French Dutchenese

Custom CEMS


Altech's custom system design services will provide a system to meet the clients' requirements. Altech Envrionment's custom CEMS utilize the make and model of instruments and peripheral equipment specified, or we can assist with determining equipment needs.

Altech Environment USA supplies custom CEMS which include a choice of:

  • Sampling Methods: direct extractive, hot/wet extractive, dilution extractive
  • Gas Analyzers: discrete, multi-component
  • Sample Conditioning Systems: probes, gas chillers (thermo electric, refrigerant or permeation)
  • Flow Monitors: ultrasonic, Pitot tube or multi-point
  • Opacity Analyzer
  • Particulate Analyzer
  • System Controller: PLC or data logger
  • Data Acquisition and Reporting System
  • Shelters: metal, aluminum, fiberglass, NEMA rating

MIR-IS Close-Coupled Multigas System


MIR-IS

Complete CEMS in one cabinet-combines infrared analyzer, SEC sampling system and probe into one.

Multiple applications - Coal/gas fired boilers. Turbines, SCR/SNCR inlet/outlet NOx control, Industrial boilers and furnaces.

Provides the benefits of in-situ analyzer with the performance of an extractive system and is cost effective.

Altech custom CEMS include choice of:

MIR-IS Features

  • Meets or exceeds 40CFR 60/75 requirements
  • Short, flexible, heated hose available for close-coupled configuration
  • On-board permeation sample dryer-no loss of soluble gases in the sample conditioning process
  • NEMA 4 temperature controlled enclosure (when required)
  • Up to six continuous gas measurements
  • Flow, temperature and pressure measurements available

Click Here to download the MIR-IS Close-Coupled Multigas System brochure

MIR 9000 Multigas Analyzer


Continuously measure from 1 - 10 gases using IR/Gas Filter Correlation

Exceptional low range performance for NO, CO, SO2

  • Remote accessibility
  • Compact Modular design
  • Low maintenance
  • Over 1,000 systems installed worldwide

MIR-9000 Features

  • Sample dried and cleaned at probe using the SEC sampling system or with conventional sample conditioning
  • Microprocessor controlled
  • Dual ranges available
  • Analog and digital outputs
  • Meets or exceeds 40CFR60/75 requirements

Applications

  • Incinerators
  • Power Plants
  • Gas Turbines
  • Petrochemical Industries
  • Process Control
  • Accredited Testing Laboratories

Click Here to download MIR 9000 Multigas Analyzer brochure.

MIR 9000 CLD System


MIR-9000-CLD

Continuously measure from 1 - 10 gases using IR/Gas Filter Correlation

Exceptional low range performance for NO, CO, SO2

  • Remote accessibility
  • Compact Modular design
  • Low maintenance
  • Over 1,000 systems installed worldwide

MIR-9000 CLD Features

  • Sample dried and cleaned at probe using the SEC sampling system or with conventional sample conditioning
  • Microprocessor controlled
  • Dual ranges available
  • Analog and digital outputs
  • Meets or exceeds 40CFR60/75 requirements

Applications

  • Incinerators
  • Power Plants
  • Gas Turbines
  • Petrochemical Industries
  • Process Control
  • Accredited Testing Laboratories

Click Here to download MIR-CLD System brochure.

MIR-9000H Heated Multi-Gas Analyzer


MIR-9000H
  • Pollutants measured Nox, O2, Thc, N20, Co2, So2, Hcl, Voc, Ch4, Co, Nh3, Hf
  • Designed to measure wet and corrosive samples
  • Perfectly suited for ammonia slip detection
  • 180°C heated measurement cell and sampling line
  • Automatic spectral interference correction
  • Reproducible and accurate, fast response time
  • Excellent calibration stability
  • Robust and reliable design in a stainless steel enclosure to withstand the harshest environmental conditions
  • Accepts and displays up to 4 external signals: pressure, temperature, flow, etc
  • Remote access for maintenance and configuration backup
  • Graphic LCD display, with interactive menu driven software; no PC required
  • No nitrogen required for calibration, low maintenance costs
  • Compliant with U.S. EPA and European EN Regulations

Click Here to download the MIR 9000H Heated Multi Gas Analyzer brochure.

Discrete Dilution or Direct Extractive Systems


discrete
  • Pre-engineered to reduce costs and delivery time
  • Meets or exceeds 40 CFR 60/75 requirements
  • Conventional equipment and design
  • Direct extractive or Dilution extractive design
  • Discrete analyzers
  • Built in data acquisition and reporting system

Click Here to download the MIR 9000H Heated Multi Gas Analyzer brochure.

MIR-FT Fourier Transform Infra-Red


MIR-FT
  • Especially designed for corrosive and reactive sample gases
  • Rugged & insensitive to vibrations
  • Excellent calibration stability
  • Automatic correction of spectral interferences
  • Fast and simultaneous measurements
  • Heated "Hot/Wet" sample system
  • Windows-based analysis and reporting software

Click Here to download the MIR-FT Fourier Transform Infra-Red brochure.

FTUV Fourier Transform UV Ammonia Analyzer


fourier
  • Engine exhaust gas monitoring
  • Emission monitoring (CEMS)
  • Process Control (DeNOX SCR and SNCR)
  • Available heated sampling module
  • Heated chamber (190°C)
  • Ultra-fast response time (Less Than 2 seconds)
  • High-speed DSP processor

Click Here to download the Fourier Transform UV Ammonia brochure

AMESA Dioxin/Furan Sampling


amesa
  • Continuous Dioxons/Furans Monitoring
  • Fully automated
  • True Isokinetic sampling (up to 6 weeks collection per cartridge)
  • EPA Method 32A compliant with TUV & MCTERTS approvals

Click Here to download the AMESA Dioxin/Furan Monitor brochure.

amesa side

BETA 5M PM CEMS


beta

Continuous particulate emission monitor by beta ray attenuation

Click Here to download the BETA 5M PM CEMS brochure.